Ohm’s Law at a Glance
Ohm’s law states that the current through a conductor is directly proportional to the voltage across it and inversely proportional to its resistance: V = I × R. A companion relationship, P = V × I, links electrical power to voltage and current. Together, these two equations mean that from any two of volts, amps, ohms, and watts, you can derive the other two. A 12 V circuit pushing 2 A through a load means the load is 6 Ω and dissipates 24 W — the calculator above solves all four values the moment you type two of them.
The Formulas
The two power variants are not new laws — they are algebraic rearrangements. When you know current and resistance but not voltage, P = I² × R skips a step; when you know voltage and resistance, P = V² ÷ R does the same. The calculator handles all six pairings automatically, including the square-root cases: given power and resistance, I = √(P ÷ R) and V = √(P × R).
Worked Examples
Example 1 — Car accessory circuit: a 12 V supply drives 2 A through a load. R = 12 ÷ 2 = 6 Ω, and P = 12 × 2 = 24 W. This is the calculator’s default, so you can see it live above.
Example 2 — Space heater: a 1200 W heater on 230 V. I = 1200 ÷ 230 = 5.22 A, and its element resistance is R = 230² ÷ 1200 = 52900 ÷ 1200 = 44.1 Ω. Notice how the V² ÷ R form gives resistance directly from the two nameplate values.
Example 3 — LED current-limiting resistor: a 9 V battery powers an LED that drops 2 V at 20 mA (0.02 A). The resistor must drop the remaining 7 V: R = 7 ÷ 0.02 = 350 Ω (use the standard 360 Ω value). Resistor dissipation is P = I² × R = 0.02² × 350 = 0.14 W, so a common ¼ W resistor has comfortable margin.
Example 4 — Light bulb forensics: a bulb rated 60 W at 120 V. Its filament resistance is R = 120² ÷ 60 = 14400 ÷ 60 = 240 Ω, drawing I = 60 ÷ 120 = 0.5 A. Check the reverse: √(60 ÷ 240) = √0.25 = 0.5 A — the square-root forms agree.
Why Ohm’s Law Runs Every Circuit
Nearly every practical electrical decision traces back to these equations. Fuse and breaker selection is Ohm’s law in disguise: a 13 A fuse on a 230 V circuit protects loads up to about 3000 W, because P = V × I. Wire heating follows P = I² × R — double the current and a wire produces four times the heat, which is why correct wire sizing matters far more than most DIYers expect. Voltage drop on long cable runs is V = I × R applied to the cable itself: 20 A through 0.5 Ω of cable loses 10 V before it ever reaches the load.
The most dramatic application is the power grid. Transmitting 100 MW at 400 V would require 250,000 A — impossible for any conductor. At 400 kV the same power needs only 250 A, and since line losses follow I² × R, raising voltage by a factor of 1000 cuts losses by a factor of a million. Every transformer on the grid exists because of Ohm’s law.
The Memory Aids: Triangles and the Power Wheel
Working electricians rarely solve equations from scratch — they use the VIR triangle. Draw a triangle with V on top and I × R below a horizontal divider. Cover the quantity you want with your thumb: cover V and you see I × R (multiply across the bottom); cover I and you see V over R (divide); cover R and you see V over I. A second triangle handles power the same way: P on top, V × I below. Between the two triangles, all six pairings are solvable without touching algebra.
The full Ohm’s law wheel packs all twelve rearrangements into one diagram — inner ring V = I × R, I = V ÷ R, R = V ÷ I; outer ring P = V × I, P = I² × R, P = V² ÷ R, plus the square-root forms. Tape it inside your toolbox lid. Within weeks you will stop reaching for the calculator on the easy cases: 24 V across 8 Ω is obviously 3 A (cover I: 24 ÷ 8), and 3 A through 8 Ω is obviously 72 W (P = I² × R = 9 × 8). The calculator above remains for the awkward numbers — 147 V across 33.5 Ω is nobody’s idea of mental math.
Ohm’s Law in AC Circuits: Impedance
With alternating current, coils and capacitors oppose changes in current, adding reactance (X) on top of plain resistance (R). The combination is impedance (Z), and Ohm’s law generalizes to V = I × Z. A contactor coil might measure 10 Ω on a multimeter — pure DC resistance — yet draw only 5.75 A from 230 V 50 Hz, because its impedance is 40 Ω: the extra 30 Ω is inductive reactance from the coil’s magnetic field fighting the alternating current.
This is why DC resistance measurements mislead on AC equipment. A motor winding that reads 2 Ω on a meter does not draw 115 A from 230 V; its running impedance is far higher, and it changes with load. The power formulas adapt as well: real power becomes P = V × I × PF, where the power factor captures how far reactance pushes current out of phase with voltage. At PF 1 — pure resistance, like heaters and incandescent bulbs — the AC formulas collapse exactly back to the DC ones, which is why a 2 kW heater behaves identically on paper whether the supply is DC or AC. For anything with significant reactance, work with impedance and power factor instead — see our three-phase and kVA to amps pages.
Common Mistakes
- Milliamps vs amps: 20 mA is 0.02 A. Forgetting the conversion makes resistor values 1000× wrong — the classic LED-killer.
- Ignoring resistor power rating: the resistance value is only half the choice. A resistor dropping significant voltage at real current must be rated for I² × R watts, with margin.
- Applying DC Ohm’s law to reactive AC loads: with motors, transformers, and capacitors, current also depends on inductance and capacitance. Use impedance (Z = V ÷ I) instead of plain resistance — see our three-phase and kVA to amps pages for AC work.
- Assuming the supply voltage is constant: batteries sag and long cables drop voltage under load. Measure voltage at the load, under load, for accurate results.
- Mixing up the power forms: P = V² ÷ R needs the voltage across that resistor, not the supply voltage when other components are in series.
Sizing Fuses and Resistors With Ohm’s Law
Ohm’s law is the everyday tool for picking protective devices and components. Fuse sizing starts from load current: a 2 kW heater on 230 V draws 2000 ÷ 230 = 8.7 A, so a 10 A or 13 A fuse is appropriate — the next standard ratings above the load, never far above. The fuse must blow before the wire overheats, which is why fuse choice always follows wire sizing, not the other way round. For motor circuits the logic differs (starting current dominates), as covered on our breaker sizing page — but for resistive loads, I = P ÷ V plus one standard size up is the whole job.
Resistor selection needs both resistance and wattage. Dropping 12 V across a 6 Ω load dissipates 24 W — a resistor rated below that will scorch, so you specify a 30 W or 50 W wirewound part, not a ¼ W film one. A classic design exercise is the voltage divider: derive 5 V for a sensor from a 12 V rail using R1 = 1.4 kΩ and R2 = 1 kΩ. Total resistance is 2400 Ω, current is 12 ÷ 2400 = 5 mA, and the output across R2 is 12 × (1000 ÷ 2400) = 5 V exactly. Power in R1 is I² × R = 0.005² × 1400 = 0.035 W — a ¼ W resistor coasts. The catch: a divider only holds its voltage when the load draws far less than the divider current, so dividers feed high-impedance inputs (sensor pins, op-amp inputs) — never motors or lamps.