Battery Runtime Calculator

How long will your battery last? Usable energy and backup time.

Calculator Input

LIVE  Live calculation — type and watch the result.

Amp-hour rating printed on the battery.
Nominal voltage: 12, 24, or 48 V.
Lead-acid ~50%, AGM ~70%, LiFePO4 80–100%.
Continuous power draw of your devices.
Typical pure sine-wave inverter: 85–95%. Ignored for DC loads.

Backup Time

—
—

Details

Enter values to calculate

Battery Runtime at a Glance

How long a battery lasts depends on three things: how much energy it stores, how much of that energy you are willing to use, and how fast your load drains it. A 100 Ah 12 V battery holds 1200 Wh in theory, but at 80% usable depth of discharge you get 960 Wh — enough to run a 200 W AC load for about 4 hours 19 minutes through a 90% efficient inverter. The calculator above turns your battery specs and load into a backup time instantly.

The Formulas

Usable energy:  Wh = Ah × V × (DoD ÷ 100)
Effective AC load:  W_eff = W ÷ efficiency
Runtime:  hours = usable Wh ÷ effective load W

Amp-hours alone mean little until multiplied by voltage: 100 Ah at 12 V is 1200 Wh, but 100 Ah at 48 V is 4800 Wh — four times the energy. Depth of discharge (DoD) then trims the total to what the chemistry tolerates, and the inverter’s efficiency inflates the load the battery actually sees.

Worked Examples

Example 1 — Camping inverter setup: 100 Ah 12 V battery, 80% DoD, 200 W AC load, 90% inverter. Usable = 100 × 12 × 0.8 = 960 Wh. Effective load = 200 ÷ 0.9 = 222.2 W. Runtime = 960 ÷ 222.2 = 4.32 h = 4 h 19 min. The inverter silently eats 22 W — over four hours that is nearly 90 Wh lost as heat.

Example 2 — LiFePO4 off-grid: 280 Ah 12 V lithium, 90% DoD, 500 W DC load (no inverter). Usable = 280 × 12 × 0.9 = 3024 Wh. Runtime = 3024 ÷ 500 = 6.05 h = 6 h 3 min. DC loads skip inverter losses entirely, which is why off-grid lighting and USB charging run straight from the battery.

Example 3 — Laptop power bank: a 20,000 mAh (20 Ah) bank at 3.7 V nominal stores 20 × 3.7 = 74 Wh. A 45 W laptop gets 74 ÷ 45 = 1.64 h = 1 h 39 min ideally; with ~85% conversion losses, expect around 1 h 24 min in practice.

Example 4 — Fridge autonomy: a small fridge averaging 1.2 kWh per day, powered by two 100 Ah 12 V lead-acid batteries at 50% DoD. Usable = 2 × 100 × 12 × 0.5 = 1200 Wh = 1.2 kWh — exactly one day of autonomy. Two cloudy days need double the bank.

Depth of Discharge by Chemistry

DoD is the single most misunderstood battery number. Draining a battery to zero rarely kills it once — it kills it slowly, by slashing cycle life. Practical limits:

Notice the economics: a 100 Ah lead-acid battery at 50% DoD gives 600 usable Wh; a 100 Ah LiFePO4 at 90% gives 1080 Wh — and lasts roughly ten times as many cycles. The sticker price comparison is meaningless without DoD and cycle life.

Inverter Losses, Peukert, and Temperature

Three effects shrink real runtime below the simple math. Inverter efficiency (85–95%) means an AC load always draws more from the battery than its nameplate watts — the calculator applies this automatically when the AC box is checked. Peukert’s law hits lead-acid hardest: discharge a 100 Ah lead-acid battery at 100 A and you will get far less than one hour, because capacity ratings assume a 20-hour discharge rate. Lithium chemistries barely notice. Cold temporarily reduces available capacity — a lead-acid battery at −18°C delivers roughly half its rated amp-hours; keep batteries warm in winter installations.

Series vs Parallel: Building a Battery Bank

One battery is rarely enough, so banks are wired in series (positive to negative, chaining voltage) or parallel (positive to positive, pooling capacity). Series adds voltage: four 100 Ah 12 V batteries in series give 48 V at 100 Ah = 4800 Wh. Parallel adds amp-hours: the same four in parallel give 12 V at 400 Ah = 4800 Wh. The stored energy is identical either way — but the system voltage changes everything downstream.

Higher voltage wins for anything above a few hundred watts. A 2000 W inverter draws 2000 ÷ 12 = 167 A from a 12 V bank but only 2000 ÷ 48 = 41.7 A from a 48 V bank — the difference between welding cable and ordinary battery cable, and between a 200 A fuse and a 50 A one. That is why RVs stay 12 V, cabins go 24 V, and serious off-grid homes run 48 V. Two warnings: never mix old and new batteries (or different capacities) in one bank — the weakest cell drags the rest down — and parallel strings above two or three batteries need careful busbar layout so every battery shares current equally. Size the resulting cables with our wire size calculator, remembering the current flows at battery voltage.

Charging: How Long to Refill

Runtime is only half the story — the battery must recharge before the next outage. Charge time follows the same energy logic in reverse: hours ≈ used Wh ÷ (charger watts × charge efficiency), with charge efficiency around 85% for lead-acid and 95%+ for lithium. Example: you used 960 Wh from the camping setup and recharge with a 20 A 12 V charger (240 W): 960 ÷ (240 × 0.85) = 960 ÷ 204 = 4.7 h = 4 h 42 min.

Real charging is slower than the math suggests because of charge stages. Lead-acid charges in bulk (constant current, fast) up to ~80%, then absorption (constant voltage, tapering current) for the final 20% — that last fifth can take as long as the first four. Lithium charges at full current nearly to the top, which is another reason solar installers prefer it: every sun-hour counts. Whatever the chemistry, size your charger or solar array from the used watt-hours, not the battery’s rated capacity — and remember that charging below 0°C damages lithium cells, so cold-climate systems need heated batteries or temperature-gated chargers.

Common Mistakes

Solar Charging: Sizing Panels From Your Runtime

The calculator tells you how fast the battery drains; solar sizing runs the same math in reverse to refill it. Panels must replace the used watt-hours within your available sun hours, derated for real-world system efficiency (~75% after panel heat, controller losses, and wiring): panel watts = used Wh ÷ (sun hours × 0.75). Our camping setup used 960 Wh overnight; with 4 peak sun hours, that needs 960 ÷ (4 × 0.75) = 960 ÷ 3 = 320 W of panels — two 160 W panels, or one 400 W panel with margin.

The charge controller is sized from panel watts at battery voltage: 320 W ÷ 12 V = 26.7 A, so a 30 A MPPT controller is the right pick (MPPT, not PWM, at this size — it converts the panel’s higher voltage into extra charging current, worth ~20% more harvest). Finally, days of autonomy decide the bank: one cloudy day needs the single-day bank we calculated; two cloudy days need double the amp-hours. Most off-grid designs target 2–3 days of autonomy for lead-acid (where deep cycling hurts) and 1–2 days for lithium (which shrugs at deep cycles and recharges faster when the sun returns).

Two installation details make or break solar harvest. Orientation and tilt: in the northern hemisphere panels face true south, tilted at roughly your latitude angle — steeper for winter-biased loads, shallower where summer cooling dominates. Even partial shade on one panel in a series string can collapse the whole string’s output, so survey for chimney and tree shadows across the seasons. Second, temperature derating: panels are rated at 25°C cell temperature, but a dark panel in full sun runs 30–40°C hotter, losing roughly 0.4% per degree — a 400 W panel delivers barely 340 W on a hot afternoon. The 0.75 system factor in the sizing formula already absorbs this, which is why careful installs land close to the estimate.

Frequently Asked Questions

How long will a 100 Ah battery last?
Depends on load: at 200 W AC through a 90% inverter with 80% DoD, about 4 h 19 min (960 Wh ÷ 222 W). Halve the load and you roughly double the time.
What is depth of discharge?
The percentage of a battery’s capacity you use before recharging. Lead-acid batteries last longest at 50% DoD; LiFePO4 tolerates 80–100%. Deeper discharges shorten cycle life.
Can I use 100% of a lithium battery?
LiFePO4 chemistry tolerates near-100% DoD, but staying around 80–90% still extends cycle life. Built-in battery management systems usually enforce a safe cutoff anyway.
Does the inverter waste power?
Yes — 5–15% of the energy becomes heat, plus a standby draw of roughly 10–30 W. That is why the calculator divides your AC load by the inverter efficiency.
What is the difference between Ah and Wh?
Amp-hours measure charge; watt-hours measure energy. Wh = Ah × volts. Only watt-hours let you compare batteries of different voltages or compute runtime against a watt load. See our amp-hours explainer.
How many batteries do I need for one day of backup?
Add up your daily watt-hours, divide by (battery Wh × DoD). Example: 1.2 kWh/day ÷ (1200 Wh × 50%) = 2 × 100 Ah 12 V lead-acid batteries.
Why does my battery die faster in winter?
Cold slows the chemical reactions — a lead-acid battery near freezing can deliver only ~65% of its rated capacity, ~50% at −18°C. Lithium handles cold better but should not be charged below 0°C.
Should I run DC loads directly from the battery?
Whenever possible, yes. Skipping the inverter saves 5–15% and removes a failure point — which is why off-grid cabins run 12/24 V lighting and USB straight from the DC bus.