240 V Circuits at a Glance
In North American homes, 240 volts feeds the heavy hitters: electric dryers, ranges, water heaters, and central air-conditioning. These run on dedicated double-pole breakers, typically 30–50 A, because even at 240 V the currents are substantial.
At PF 1.0, 1 kW at 240 V ≈ 4.17 A. A 5 kW dryer therefore draws about 20.83 A — comfortably inside a 30 A circuit but already past what any 120 V outlet could supply. Formula: I = (kW × 1000) ÷ (240 × PF).
How 240 V Is Made: Two 120 V Legs
American homes receive split-phase service: a center-tapped transformer delivers two 120-volt legs, L1 and L2, that are 180 degrees out of phase. Each leg measures 120 V to the neutral, but across the two legs the voltages add — giving 240 V. A pure 240 V circuit connects across L1 and L2 and skips the neutral entirely, while appliances like dryers and ranges use a four-wire feed (two hots, neutral, ground) so their 120 V controls and 240 V heating elements can share one cable.
Four-wire circuits add a neutral so mixed 120/240 V appliances can run both voltages from one cable. The neutral only carries the imbalance between the two legs — if the 120 V loads on each leg are equal, the neutral current cancels toward zero. That is why a pure 240 V load, like a water heater with no 120 V controls, needs no neutral at all: the two hot legs are perfectly balanced by design. That center tap is the neutral bar you see in every residential panel.
Double-Pole Breakers
A 240 V circuit is protected by a double-pole breaker: two breaker poles joined by a single handle so both hot legs disconnect together. If one leg faults, both trip — you never want one hot leg of a 240 V circuit staying live. Modern 240 V outlets follow the NEMA 6 and 14 series: a 14-30 receptacle for dryers, a 14-50 for ranges and many EV chargers, each keyed so the wrong plug cannot fit. One rule is absolute: never cobble together two single breakers — only a factory-made double-pole unit guarantees both legs open together.
Size the wire to the breaker, not the load: 10 AWG copper for a 30 A double-pole, 8 AWG for 40 A, and 6 AWG for 50 A. Older three-wire dryer and range circuits (hot-hot-neutral, no ground) were legal in their day but are no longer installed — a new 240 V circuit always gets a separate ground.
Which Appliances Use 240 V
- Electric clothes dryer (about 5 kW)
- Electric range and cooktop (8–12 kW)
- Electric water heater (4.5 kW)
- Level 2 EV charger (7.2–11.5 kW)
- Central air conditioner or heat pump (3–5 kW)
- Electric baseboard heating and large workshop tools
The dividing line is power: anything much above 2–3 kW moves to 240 V, because the current at 120 V would demand impractically thick wire and oversized breakers. A 3 kW load makes the point concrete: at 120 V it draws 25 A, but at 240 V only 12.5 A — half the current, a quarter of the resistive losses, and a much smaller breaker.
Breaker Sizing for Common 240 V Loads
For continuous loads (three hours or more), the breaker must be at least 125 percent of the load current — the 80 percent rule flipped around. Currents below assume 240 V and power factor 1.0 unless noted.
| Appliance | Power | Current | 125% minimum | Standard double-pole |
|---|---|---|---|---|
| Clothes dryer | 5 kW | 20.83 A | 26.04 A | 30 A |
| Water heater | 4.5 kW | 18.75 A | 23.44 A | 25 A |
| EV charger | 7.2 kW | 30.00 A | 37.50 A | 40 A |
| Electric range | 9.6 kW | 40.00 A | 50.00 A | 50 A |
| Central AC (PF 0.85) | 3.5 kW | 17.16 A | 21.45 A | 25 A |
| Baseboard heater | 2.5 kW | 10.42 A | 13.02 A | 15 A |
The wire must be sized to the breaker: 10 AWG copper for 30 A, 8 AWG for 40 A, 6 AWG for 50 A.
Worked Examples
Example 1 — 5 kW dryer
Current: 5,000 ÷ 240 = 20.83 A. Continuous-load minimum breaker: 20.83 × 1.25 = 26.04 A, so the next standard size is a 30 A double-pole breaker on 10 AWG copper.
Example 2 — 7.2 kW EV charger
Current: 7,200 ÷ 240 = 30 A. Minimum breaker: 30 × 1.25 = 37.5 A, so a 40 A double-pole breaker. And because charging runs for hours, the charger must be configured to draw no more than 32 A — 80 percent of the 40 A breaker.
Example 3 — 9.6 kW range
Current: 9,600 ÷ 240 = 40 A. Minimum breaker: 40 × 1.25 = 50 A, so a 50 A double-pole breaker on 6 AWG copper. Ranges cycle their elements rather than running flat-out, but they are still sized as continuous loads.
Common Mistakes
- Sizing the breaker to the exact load current and forgetting the 125 percent rule for continuous loads — a 30 A breaker on a 30 A EV charger is undersized.
- Matching the breaker but not the wire: a 50 A breaker demands 6 AWG copper, not the 10 AWG left over from a dryer circuit.
- Assuming every 240 V load has a power factor of 1.0 — air-conditioner compressors run around 0.85, which raises the current.
- Feeding a 240 V EV charger from an old three-wire dryer outlet — the grounding arrangement of a legacy 10-30 is not a safe EV supply.
Safety Note
240 volts delivers a shock that is far more likely to be lethal than 120 V, and the fault current available at a panel is enormous. Never work inside a panel unless you are qualified, never backfeed a generator through a dryer outlet, and treat every double-pole breaker with the respect two hot legs deserve. When in doubt, an electrician’s hour costs far less than a hospital visit.